Kitchenaid Dishwasher Fault Codes
Drawer Dishwasher Codes
The control has been designed to test Sensors,
Memory, and Loads. During the Field Service
Test, if a fault has been detected, the test will
abort. A Memory / Software Check will occur
immediately after the test is started. If an error
is detected, the Cancel LED will flash with a
fault code per the Fault Code Table. If multiple
errors have been detected they will be shown
one at a time.
Errors flash 2 • seconds ON, 0.5 seconds
OFF • Any key press will exit the Error Display
Mode • All errors are cleared after exiting the Error
Display Mode
Fault Codes
Anti Bacterial/ |
Normal Wash | China Gentle | Quick Wash | Quick Rinse | |
|---|---|---|---|---|---|
| Main Control Board General Failure | - |
- |
- |
- |
X |
| Main Control Board Memory Corruption | - |
- |
X |
- |
X |
| User Interface General Failure | - |
X |
- |
X |
- |
| User Interface Stuck Key | - |
X |
- |
X |
X |
| Dispenser Current Sense Error | X |
- |
- |
- |
- |
| Water Inlet Valve Current Sense Error | X |
- |
- |
- |
X |
| Wash Pump Current Sense Error | X |
- |
- |
X |
- |
| Dry Fan Current Sense Error | X |
- |
X |
- |
- |
| Drain Pump Current Sense Error | X |
- |
X |
- |
X |
| Wash Heater Current Sense Error | X |
- |
X |
X |
X |
| Drain Solenoid Current Sense Error | X |
X |
- |
- |
- |
| Wash Thermistor Out of Range | X |
X |
- |
X |
X |
| Turbidity Sensor Out of Range | X |
X |
X |
- |
- |
| Turbidity Sensor Failed to Calibrate | X |
X |
X |
- |
X |
| Fill Sensing Error | X |
X |
X |
X |
X |